Bit
Explanation for bit set
12
Overflow of the FIFO. The bit is cleared when writing the control flags, RO.
13
Ethernet error The bit is cleared when writing the control flags, RO.
1)
Only one of the various fill modes can be active at any given time, meaning you can only
ever set one of these bits.
9.7.4

Measuring channel objects

General channel settings
As subindex 0 is not usable as a parameter, the indices here extend from 1
to 32 and not from 0 to 31 as in the signal references table. So you always
have to add 1 to the values in the
Enter 4 for the gross signal and 5 for the net signal for example.
Index
Subindex
0x44F0
3 ... 32
See
„List
of signal
0x44F1
refer-
ences" on
page 218
0x44F2
+ 1
0x44F3
180
Function
Read (measurement) val-
ues.
Read or write channel
name.
Read or write unit.
See also
„Additional CoE
objects for EtherCAT/Twin-
CAT" on page
168.
Number of one decimal
places; only used for dis-
play in web browser.
„List of signal references" on page
Value
FLOAT, RO.
STRING, length ≤ 22 charac-
ters.
STRING, length ≤ 10 charac-
ters, parameters 1 ... 10 and 32
RO.
0 ... 6, UINT8.
218.
ClipX
Operation via fieldbus