Herunterladen Inhalt Inhalt Diese Seite drucken

HBM ClipX Bedienungsanleitung Seite 153

Vorschau ausblenden Andere Handbücher für ClipX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Register for transferring from Modbus to ClipX (output)
See also
Holding
Coil
register
0 ... 31
0 ... 1
32 ... 47
2
3
4 ... 5
6 ... 7
8 ... 9
10 ... 11
12 ... 13
14 ... 15
Response to read request sent to object directory
Register
Meaning
16
Index
17
Bits 0 ... 7: Subindex
Response to write request sent to object directory
Register
Meaning
18
Index
19
Bits 0 ... 7: Subindex
20 ... 21
Value
ClipX
Operation via fieldbus
„Data transfer from the controller to the ClipX" on page
Meaning
Control word.
See
„The control word" on page
Coil 0 controls bit 0 'Zero'.
Fieldbus flags
Parameter set
External FB value 1 (Fieldbus 1)
External FB value 2 (Fieldbus 2)
Threshold 1
Threshold 2
Threshold 3
Threshold 4
158.
Format
UINT16
UINT16
Format
UINT16
UINT16
Dependent on object
122.
Format
Bit array
Bit array
UINT16
REAL
REAL
REAL
REAL
REAL
REAL
151

Werbung

Inhaltsverzeichnis
loading