Herunterladen Inhalt Inhalt Diese Seite drucken

Ac Dynamo And Regulator [Z400-B· Z430-B' 0600-B' 0640-B]; Checking - Kubota Z400-B Handbuch

Inhaltsverzeichnis

Werbung

[4] AC DYNAMO AND REGULATOR
[Z400-B· Z430-B· D600-B' D640-B]
CHECKING
No-Load Dynamo Output
1. Disconnect the lead wires from the AC dynamo.
2. Start the engine and operate the AC dynamo at the
specified speed.
3. Measure the output voltage with a volt meter.
If the measurement is not within the specified values,
replace the AC dynamo.
I
v
~
O]()9F095
Regulating Voltage
1. Complete the charging circuit with a fully charged battery
and operate the dynamo at the specified speed.
2. Measure the battery voltage with a volt meter.
3. If the measurement is not within the specified values,
replace the regulator.
Regulating
Factory
14 to 15V
~_v_o_lt_ag_e
__
~
.......
~~
___ __
__ ______
s~
ci_fi_ca_t_io_n__
~_a_t_5_2_OO
rp_m
~
S-155