Radiator Cap Opening Pressure
1. Set a radiator tester on the radiator cap.
2. Apply the pressure of 88 kPa (0.9 kgf/cm2, 13 psi) and
measure the time for the pressure to fall to 59 kPa
0.6
kgf/cm 2 ,
9
psi).
3.
If the measurement is less than the specified value, replace
the radiator cap.
Pressure
falling time
Factory
specification
more than 10 seconds
from 88 to 59 kPa
(from 0.9 to 0.6 kgf /cm
2
,
from 13 to 9 psi)
CU19FU68
DISASSEMBLY AND ASSEMBLY
IJJ09FU83
IJI09F084
Thermostat
1.
Remove the thermostat cover.
2.
Remove the thermostat.
(When reassembling)
• Apply liquid gasket (Three Bond 1215 or equivalent) to
the gasket.
Water Pump
1.
Remove the water pump from the gear case cover.
2. Remove the fan, the pulley anj the flange (1).
3.
Press out the water pump shaft
(2)
with the impeller
(5)
on it.
4. Remove the impeller from the water shaft.
5. Remove the mechanical seal (4).
(When reassembling)
• Apply liquid gasket (Three Bond 1215 or equ iva lent) to
the gasket.
• Replace the mechanical seal with the new one.
(1)
Water Pump Flange
(2)
Water Pump Shaft
(3) Water Pump Body
(4) Mechanical Seal
(5) Impeller