Test the voltage at the Dryer LED (LED6)
1.
Verify that J8 is connected on the Motion PCA (A2).
2.
Disconnect the wire connector from the LED.
3.
Test the voltage at LED6: 0 Vdc unblocked, 2.14 Vdc with the LED on at pins 5A to 6A on W32P9-W34J9.
„Drum wiring diagram" auf Seite 2265
1
Is the voltage correct?
1
No
Yes
Replace the Dryer LED (LED6)
1
2
1.
Replace LED6.
Check the wire harness between the Motion PCA (A2) and the LED
1.
Check the wire harness between A2 and the LED. Repair as needed.
1
„Drum wiring diagram" auf Seite 2265
Replace the Motion PCA (A2)
1.
Replace A2.
„Motion PCA (A2)" auf Seite 710
1406 Kapitel 8 Hardware fault trees