1
2
3
1
2
3
1
2
3
1
2
3
Replace the Trays 2, 3, and 4 Controller PCA (A23)
1.
Replace A23.
„Trays 2, 3, and 4 Controller PCA (A23)" auf Seite 341
1
2
VORSICHT!
Test the voltage at the 32 Vdc and 5 Vdc test points on the Power Distribution PCA (A1)
1.
Test the voltage at the 32 Vdc and 5 Vdc test points on A1.
„Power Distribution PCA (A1) diagram" auf Seite 2312
1
Is the voltage 32 Vdc at the 32 Vdc test point and 5 Vdc at the 5 Vdc test point?
No
Yes
1
Check the wire harness between the Trays 2, 3, and 4 Controller PCA (A23) and the Power Distribution PCA (A1)
1.
Check the wiring between A1 and A23.
2.
Repair or replace as needed.
„Power Distribution PCA (A1) diagram" auf Seite 2312
1
2
„Trays 2, 3, and 4 controller PCA diagram" auf Seite 2298
DEWW
Check the resistance at the Tray 2, 3, and 4 Ambient Temperature sensor (SN41)
1.
Verify that J5 is connected on the Trays 2, 3, and 4 Controller PCA (A23).
2.
Disconnect the connector from SN41.
3.
Check the resistance at pins 2 to 4 on the wire harness.
„Trays 2, 3, and 4 assembly wiring diagram" auf Seite 2296
HINWEIS:
If SN41 is touched, the temperature reading changes quickly.
Is the resistance approximately 12000 ohms (70F/20C) and 9600 ohms (80F/26C) at SN41?
No
Yes
Check the following conditions
1.
Verify that the Tray 2, 3, and 4 Ambient Temperature sensor (SN41) is clean and has no
obstructions.
2.
Check the electrical connections and wiring between SN41 and the Trays 2, 3, and 4 Controller
4
PCA (A23).
Replace the Tray 2, 3, and 4 Ambient Temperature sensor (SN41)
1.
Verify that SN41 is clean and has no obstructions.
2.
Check the electrical connections and wiring between SN41 and the Trays 2, 3, and 4 Controller PCA (A23).
3.
If SN41 is clean and the connections are secure, then replace the sensor.
„Sensoren Fächer 2, 3 und 4" auf Seite 343
VORSICHT!
Use an ESD strap.
Use an ESD strap.
A1.02C1:Tray 2, 3, and 4 Ambient Temperature sensor (SN41) 1215