Test the voltage at the IDO Diverter solenoid (SOL2)
1.
Verify that J14 is connected on the Motion PCA (A2).
2.
Disconnect the wire connector from the solenoid.
3.
Test the voltage at SOL2: 20 Vdc at pins 1 to 2 on W19P2-SOL2.
„IDO paper path 1 wiring diagram" auf Seite 2285
1
Is the voltage correct?
1
No
Yes
Replace the IDO Diverter solenoid (SOL2)
1.
Replace SOL2.
1
2
„IDO Diverter solenoid (SOL2)" auf Seite 461
Check the wire harness
1.
Check the wire harness and connections between the Motion PCA (A2) and the IDO Diverter solenoid (SOL2).
„IDO paper path 1 wiring diagram" auf Seite 2285
1
2.
Repair as needed.
„D4.0705: Motion PCA (A2) power not good" auf Seite 1469