Herunterladen Diese Seite drucken

HP CM8060 Color MFP Kundendienst Handbuch Seite 1423

Vorschau ausblenden Andere Handbücher für CM8060 Color MFP:

Werbung

B2.02E3: Close left-side upper panel
Initial Steps
1.
„IDO component locator" auf Seite 2365
HINWEIS:
Set DVM to the appropriate range for the voltage.
VORSICHT!
Be careful when working around electricity.
Moving parts can cause injury.
ACHTUNG:
Do not use frame as ground.
Test the Left-side Upper Panel switch (SW8)
1.
Manually activate SW8.
„IDO component locator" auf Seite 2365
TIPP:
Click Subsystems, click Paper Path, and then click IDO Sensors, Solenoids, LEDs.
Does the switch work?
No
Yes
Service the left-side upper panel
1.
Check the alignment of the left-side upper panel to the Left-side Upper Panel switch (SW8).
1
2.
Check the left-side upper panel hinges.
Check the following conditions
1.
Verify that the switch is correctly located.
2.
Clean the switch and the surrounding area.
3.
If the switch has a flag actuator, check that the flag actuator has free movement.
4.
Check the wire harness between the Left-side Upper Panel switch (SW8) and the Motion PCA (A2).
„IDO component locator" auf Seite 2365
Test theLeft-side Upper Panel switch (SW8)
1.
Manually activate SW8.
„IDO component locator" auf Seite 2365
TIPP:
Click Subsystems, click Paper Path, and then click IDO Sensors, Solenoids, LEDs.
Does the switch work?
No
Yes
1
„Final activities" auf Seite 24
DEWW
B2.02E3: Close left-side upper panel 1357