11
Technical data
Exceeding the load specifications
RK MultiControl II duo/quadro
Properties
Dimensions
Weight
Supply voltage (primary)
Maximum current
consumption (primary)
Nominal power
Standby input power*
Maximum number of drives
Maximum output current
Nominal and output voltage
Duty cycle (DC)
Protection class
Protection rating
Room temperature
Air pressure
Relative air humidity
* Standby input power is higher in combination with Multilift I/Multilift synchron
288
NOTICE!
Material damage due to load specifications being
exceeded!
If the load specifications defined by
RK Rose+Krieger GmbH are exceeded, there is a risk of
personal injury and material damage.
– Never exceed the load specifications.
MultiControl II duo
800 g
< 0.5 W
2
Example: 20 mins cycle time (4 mins operating time,
Control RK MultiControl II duo/RK MultiControl II quadro
RK MultiControl II quadro
240 mm x 105 mm x 56 mm
100 - 240 VAC, 50/60 Hz
3.5 A bei 100 VAC
3.0 A bei 115 VAC
1.5 A bei 230 VAC
350 VA
5 A per drive, 10 A total
28.5 VDC ± 2 %
with nominal load 20 % DC:
16 mins rest time)
I, secondary SELV
IP20
+5 °C - +40 °C
700 hPa - 1600 hPa
30 % - 75 %
1000 g
< 1.0 W
4