Pin
1
2
3
4
5
6
The signal contact inputs UP and DOWN can be switched by buttons (not switches) to
position the drives to +12 VDC.
4.5.4
Pin
1
2
3
4
5
6
7
8
Control RK MultiControl II duo/RK MultiControl II quadro
Function
Description
GND
-
◼ Signal contact input
RS485 B
Control BUS
◼ Contact type: NO (high active)
UP
◼ Voltage: maximum 12 VDC
◼ 12 V ± 10 %
◼ Maximum 20 mA
12 VDC
◼ Signal contact input
RS485 A
Control BUS
◼ Contact type: NO (high active)
DOWN
◼ Voltage: maximum 12 VDC
DATA interface - RK MultiControl II duo/quadro
Figure 14 - DATA interface contacts
Function
Description
GND
-
RS485 B
Serial interface for communication between
the control units (sync BUS)
Sensor 2
No set function
◼ 12 V ± 10 %
Sensor 1
Safety edge
◼ Maximum 20 mA
12 VDC
RS485 A
Sync BUS
Sensor 3
No set function
Sensor 4
External stop input
page 192
page 196
Wire colour
Brown
Green
White
Pink
Yellow
Grey
Wire colour
Brown
Green
White
Grey
Pink
Yellow
Black
Blue
183