Herunterladen Diese Seite drucken

RK Rose+Krieger Gesamt RK MultiControl II duo Montageanleitung Seite 282

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Table of error messages
Code
Description
Drive 1 motor current
„E2"
too high
Drive 2 motor current
„E3"
too high
Permitted duty cycle of
„E4"
the system exceeded
Blockage detected on
„E5"
drive 1
Blockage detected on
„E6"
drive 2
Intermediate circuit
„E7"
undervoltage/ voltage in
the control too low
„E8"
Drive 1 not detected
Difference between
„E9"
drive 1 and drive 2 too
great
Lag error between
„E11"
controller 1 and drive 1
Lag error between
„E12"
controller 2 and drive 2
282
Troubleshooting
The control detects that a drive is drawing too much current.
◼ Mechanical overload of the system
If the error occurs frequently, check for the following:
◼ Possible drive defects
The maximum duty cycle of 20% at 20 mins has been
exceeded. Wait until the error message disappears.
The control has detected an abruptly occurring excessive
current at the drive, which indicates a mechanical blockage.
Check the system for mechanical blockages and remove them
as necessary.
The error message remains displayed for as long as the
undervoltage is detected in the control (even when the
control is switched off).
Check the voltage supply (mains cable).
A drive that is suitable for the configuration of the control
◼ Disconnect the mains cable
must be inserted in drive slot M1 on the control.
◼ Check the connections
◼ Carrying out initialization run
◼ Make sure the drives are suitable for the control
◼ Make sure all drives are working correctly
◼ Check the system for mechanical load
◼ Carrying out initialization run
If the error message is still displayed, the control or a drive
could be faulty. Contact RK Rose+Krieger GmbH.
The drive does not move at the specified speed and/or may
◼ Check the drive for excessive load
be faulty.
◼ Make sure the correct drives are set in the control
If the error message is still displayed, the control or a drive
could be faulty. Contact RK Rose+Krieger GmbH.