272
No.
Parameter
SPP detection direction for collision detection:
99
0 - up/down; 1 - up; 2 - down
SPP collision detection mode:
1 - without error;
100
2 - error;
3 - automatic free-up
SPP collision detection mode 3 free-up
101
distance [inc.]
Low speed area before the final position in
retract travel direction [inc.].
When retracting, the drive stops in the set
102
position. When the
the drive continues to move at reduced speed
(parameter 14).
Hand switch with 2 buttons, stroke reduction
[inc.].
When moving using the hand switch with
103
2 buttons, the stroke is shortened in the
extend travel direction by the set number of
increments.
107
Definition of the drive type for drive group 2
◼ 0 - drive group management not
Definition of group classification for the drives:
◼ 2211 - drive connections 1 & 2 belong
activated
109
to group 1/drive connections 3 & 4
belong to group 2
Definition of the Hall sensor ratios from group
1 to group 2.
111
The parameter is set to 10000 (factor 1.0) in
the factory.
button is pressed again,
*= see „11.2 Configuration label" on page 289
Control RK MultiControl II duo/RK MultiControl II quadro
Default
Min.
(MLII)
0
0
1
1
150
0
0
0
0
0
See conf.*
10
0
2211
10000
2000
Max.
2
3
32000
65550
65550
99
2211
60000

Werbung