Maintenance plan
Interval
Weekly
Monthly
Once a year
9.3
Troubleshooting
Error messages
Resetting error messages
Control RK MultiControl II duo/RK MultiControl II quadro
Maintenance work
Check the hand switch for soiling. If necessary,
clean the hand switch with a clean cloth.
Important: Do not use cleaning agents
containing solvents!
Check the electrical connections between the
control unit and the drives for mechanical stress
and to make sure they are firmly in place.
Carry out a safety inspection of the control unit
as per DGUV V3.
Error messages are displayed on the display screen of the hand
switch with a error code (e.g. 'E21').
The error code can also be signalled in code by the LED display of
the control.
Further information:
„Table of error messages" on page 282
To reset the error message, press the function key
To reset the error message, press and hold both function keys
for 5 s.
Example error code 'E21' :
Long pause
2x flash
paws
(repeat)
Personnel
Assembly staff
Qualified electrician
Qualified electrician
Pause
1xflash
.
long
281