8.5.4
250
Deactivating stroke limitation
⇨ The lower final position determined or set during the initialization run
3.
Select 'Deactivate lower stroke limit' (Figure 101).
is applied.
'Stop functions' menu
8.5.4.1
'Safety edge' menu
A safety edge supplied by the operator can be connected to
the RK MultiControl II to safeguard crushing and shearing
points
The safety edge is deactivated in the factory.
◼ The operator's safety edge has been connected.
Prerequisites:
The main menu for the hand switch is displayed.
Selecting a menu
Select the menu via 'Control' → 'Stop functions' → 'Safety edge'
1.
(Figure 102).
Figure 101 - Deactivating stroke limitation
⮱
page 192.
Figure 102 - Selecting a menu
Control RK MultiControl II duo/RK MultiControl II quadro
⮱
page 192
⮱
8.3 on page 215