Control RK MultiControl II duo/RK MultiControl II quadro
Activating collision detection (SPP)
3.
Set the sensitivity of collision detection for the selected direction of travel
(in this case: 'Sensitivity high', Figure 110):
High: Detection threshold 50 mA (default value for Multilift II)
Medium: Detection threshold 150 mA (default value for Multilift II)
Low: Detection threshold 250 mA (default value for Multilift II)
User defined: Adjustable detection threshold from 0 - 4000 mA
⇨ Collision detection has been activated.
Figure 110 - Activating the collision detection menu
Deactivating collision detection (SPP)
4.
Select the direction of travel 'Extend' or 'Retract' (in this case: 'Retract',
Figure 111).
When drive group management is activated, set
collision detection (SPP) separately for each drive group.
Figure 111 - Selecting the direction of travel
255