Actual values

All available parameter numbers (0 to 999) can be entered into the actual value parameters, sorted according to
destinations (refer to the following).
The parameter value of the entered parameter number is output at the selected destination.
Note:
Destinations:
P655
P680
Destination, options:
P664
P690
P694
For telegram data transfer (P680,P690,P694), it is generally necessary/practical to assign "Word 01 of the
telegram (PZD)" with status word 1 (r968 or r552)!
4-28
ENGLISH
- When specifying parameter numbers, which are indexed, the value of the first index
(.i001) is always output!
- When specifying "0", no output is made to the appropriate destination!
"CUR-AA actual values"
Output via the CUR control terminal strip (Section 3.3)
Analog output 1 (-X102:14 / reference potential -X102:15)
(refer to Section 4.3.5 "analog output")
"SST1 actual values"
Output via the basic converter interface SST1
Indices:
(refer to Section 4.3.6.1 "basic converter interface SST1")
"SCI-AA actual values"
Output via the SCB1 interface with SCI1
(also refer to the Instruction Manual for the option boards)
Indexes:
"SCB actual values"
Output via the SCB1 interface with peer-to-peer protocol or SCB2
(also refer to the Instruction Manual for the option boards)
Indexes:
"CB/TB actual values"
Output via the CB or TB interface
(also refer to the Instruction Manual for the option boards and Sections 4.3.6.2 "DPR")
Indexes:
i001
Word 01 of the telegram (PZD)
i016
Word 16 of the telegram (PZD)
i001
Destination: Analog output 1 from slave 1
i002
Destination: Analog output 2 from slave 1
i003
Destination: Analog output 3 from slave 1
i004
Destination: Analog output 1 from slave 2
i005
Destination: Analog output 2 from slave 2
i006
Destination: Analog output 3 from slave 2
i001
Destination: Word 01 of the telegram (PZD)
i016
Destination: Word 16 of the telegram (PZD)
i001
Destination: Word 01 of the telegram (PZD)
i016
Destination: Word 16 of the telegram (PZD)
NOTE
Siemens AG
6SE7087-6AK85-0AA0
Common Rectifier
Operating Instructions
09.02