Parameter List
PNU
OP1S parameter name
Description
*
: Conf.
Par.
5.14

Modulator

P773
Deadband Convert
The reversing threshold of the auto-reversing module (in rectifier direction)
If the (signed) setpoint of the DC link current (output of the DC link voltage
controller on the output side of the limiting module) exceeds the value of +
0.05% set with this parameter, the firing pulses of the rectifier bridge are
enabled. These pulses are inhibited if the setpoint of the DC link current
drops below the value set here.
RDS parameter
PNU=305Hex; Type=O2; Scaling: 1Hex
P774
Deadband Invert
The reversing threshold of the auto-reversing module (in regenerating
**
direction)
If the (signed) setpoint of the DC link current (output of the DC link voltage
controller on the output side of the limiting module) exceeds the value of -
0.05% set with this parameter, the firing pulses of the rectifier bridge are
enabled. These pulses are inhibited if the setpoint of the DC link current
drops below the value set here..
RDS parameter
PNU=306Hex; Type=O2; Scaling: 1Hex
P775
Min Gating Angle
Alpha G limit (rectifier stability limit)
RDS parameter
PNU=307Hex; Type=O2; Scaling: 1Hex
P776
Max Gating Angle
Alpha W limit (inverter stability limit)
RDS parameter
PNU=308Hex; Type=O2; Scaling: 1Hex
P777
Max Gating Angle Ramp
Transition ramp of the alpha W limit from pulsating to continuous DC (for
currents < pulsating threshold, the control angle is limited to 165°, for
currents > (pulsating threshold+P777) to P776 with linear interpolation
inbetween)
RDS parameter
PNU=309Hex; Type=O2; Scaling: 1Hex
5-36
ENGLISH
∧ 0.01 %
=
∧ 0.01
=
∧ 1 °el
=
∧ 1 °el
=
∧ 1 %
=
Value range
Display
[phys. unit]
Indices
Selection text
Factory-
setting
0.01 to 100.00
4
[%]
0.01
-100.00 to -0.01
4
[%]
-3.00
0 to 120
4
0
[°el]
120 to 165
4
150
[°el]
0.00 to 100.00
4
[%] of P075
20.00
Siemens AG
6SE7087-6AK85-0AA0
Common Rectifier
Operating Instructions
09.02
See
Modify
(access /
status)
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
B
3/
BR
3/
BR