Parameter List
Parameter list; Summary of the abbreviations
Example:
PNU
OP1S - Parameter name
Description
*
: Conf.
Par.
P329
Pre-charging time
1)
Pre-charging time of the DC link
8)
RDS parameter 2)
PNU=149Hex; Type=O2; 3) Scaling: 1Hex
1) An
under the parameter number means that this is a confirmation parameter, i.e. the modified value does not become active until the
*
P key is pressed.
2) Abbreviations for indexed parameters
RDS
Reserve data set parameter with 4 indices; changeover with control word 2, bits 18 and 19
G/R
Parameter with changeover feature for basic and reserve setting in control word 2, bit 30
3) Specification of parameter type
O2
16-bit value without sign
I2
16-bit value with sign
V2
Bit-coded quantity
L2
Nibble-coded quantity
4) Scaling for access via the PKW mechanism
If necessary: Specification of scaling group for process data (PZD)
PZD group
0 or no specification
1
5) Access stage (P051), starting at which a parameter can be modified or displayed
1
Operator input
2
Standard mode
3
Expert mode
4
Factory-set parameters
6) Specification of the operating states in which the parameter can be displayed
7) Specification of the operating states in which the parameter can be displayed
6) 7) Operating states:
U
MLFB input
H
Hardware
configuration
A
Drive setting
B
Ready (incl.: fault )
R
(R) Run
8) An
under the parameter number means that this parameter does not exist with a 6SE70 rectifier unit (P070 (MLFB) ≥ 101).
**
9) A factory setting value in brackets means that the specified value only applies for P077=0. See Section 4.3.9.1 "Generate factory setting"
for more details.
5-2
ENGLISH
∧ 1 4)
=
PZD scaling
As for PKW scaling
4000Hex = 100%
o 000
o 002, o 004
o 005
o 007, o 008, o 009,
o 010, o 011, o 012, o 021
o 014, o 015, o 018
Value range
Display
[phys. unit]
Indices
Selection text
Factory
setting
0 to 9999
4
500 9)