Maintenance
8.2.3
Power interface module spare parts
Load resistors:
Replacement modules are supplied without load resistors (e.g. take them over from the original module)!
No liability will be accepted for damage caused by the installation of incorrect load resistors.
If the load resistors (R75 to R78) are not installed, the converter will be destroyed.
Dimensioning of the load resistors:
I dav [A]
Rating plate
821
1023
1333
1780
774
1023
1285
1464
1880
774
1023
1285
1464
1880
Resistors of series W97041.. tolerance: 0.50% for
The load resistance setpoint refers to the DC link current I
8-6
ENGLISH
NOTE
R75 R76
[Ω]
Voltage class 480V
4,7
4.7
18
8,2
Voltage class 600V
4,7
4,7
10
12
8,2
Voltage class 690V
4,7
4,7
10
12
8,2
0.25% for 10Ω < R < 47Ω
0.10% for
R77 R78
[Ω]
10
4,7
12
11
11
4,7
33
12
10
11
4,7
33
12
10
R ≤ 10Ω
R
and R
79
R ≥ 47Ω
stated on the rating plate.
dav
R79 R80
[Ω]
10
12
12
12
12
12
12
13
11
12
12
12
13
11
not envisaged on A1681.
80
Siemens AG
6SE7087-6AK85-0AA0
Common Rectifier
Operating Instructions
09.02