09.02
A few seconds after initialization of the OP1S, the display
automatically switches to the operating display.
From the operating display, you can enter the basic menu by
pressing the <P> key. Here either "free access" to all parameters
or different functions can be selected. Details of the functions can
be found in the OP1S operating instructions.
In the state "free access", parameterization of the device is
possible.
If you press the <R> key (several times if necessary), you can
return to the operating display.
With SIMOVERT 6SE70 the following values are displayed on the operating display:
1st line
DC link current actual value r035 [%]
2nd line
# DC link voltage actual value r037 [%]
3rd line
* DC link voltage setpoint r036 [%]
4th line
Operating state r001
The following parameters affect the function of the OP1S or of the interface SST1:
P050 (language selection), P051 (access level), P053 (parameterization enable), P054 (OP backlighting), P683
to P687 (interface settings)
Control bits of the operator panel OP1S:
(See also the operating instructions for the OP1S)
Communication between the OP1S and the SIMOVERT device is performed via the interface G-SST1 (RS485)
using the GPI protocol.
By pressing the appropriate key on the OP1S, it is possible to execute functions. The OP1S sets the
appropriate control word bit in PZD word 1 by means of transmission by the GPI protocol. (For details of the
control word bits, see Chapter 4.3.1.1)
For activation of the required function, parameterization as shown in the table below is required.
Key on OP1S
On/off key (I / 0)
Reset
Jog
Reversal
* ) Acknowledgment of the fault messages using the <Reset> key of the OP1S is only possible in the operating
display, i.e. the operating display must first have been selected by pressing the <Reset> key (several times).
Independently of that, acknowledgment is always possible by pressing the <P> key on the PMU.
The predecessor of the OP1S (the OP1) cannot be used with software version V4.0 and higher because of its
differing coupling mechanisms! The OP1S, however, is a suitable replacement for the OP1 if used with older
device software.
Siemens AG
6SE7087-6AK85-0AA0
Common Rectifier
Operating Instructions
Function
ON / OFF1
Acknowledgment * )
Jogging
U d reduction
Regenerative
feedback enable
NOTE
DC link voltage r006 [V]
Bit in PZD word 1
Bit 0
Bit 7
P565, P566, or P567 = 2001
Bit 8
Bit 11
Bit 12
Operating display
<P>
<R>
Basic menu
<P>
<R>
Free access
Bus addr.
Activation by
P554 = 2001
P568 = 2001
P571 = 2001
P572 = 2001
ENGLISH
Options
9-5