06.01
Common
6SE70..-.....-0AA0 37-7FH85 41-0FH85 41-3FK85 41-5FK85 41-8FK85
Rectifier
Rated voltage, rated frequency, rated current
Rated voltage
Input U
n
Output U
dn
Rated frequency f
n
Input
Output
Rated current I
n
Input (rms value) AC
Output (average) DC
Load class II acc. EN 60146-1-1
Rated output current average
Base load duration
Excess output current
average
Excess current duration
Losses, cooling, power factor
Power factor
Mains cosϕ
1N
Power dissipation
− Maximum
Cooling air requirement
Sound pressure level, dimensions, weight
Sound pressure
level of fan
Size
Width
Height
Depth
Weight app.
"Parallel units" (-0AD0) of size K for connecting in parallel have the same technical data as the corresponding
"basic units" (-0AA0). Please note the unit correspondence and notes of Section 3.7!
The permissible output current in parallel mode is reduced (due to current division between the power sections)
by 10 % as compared to the sum of the rated currents of the separate power sections.
Siemens AG
6SE7087-6AK85-0AA0
Common Rectifier
Operating Instructions
V
Hz
A
671
774
A
704
s
A
1057
s
kW
3,30
3
m
/s
0,55
50Hz
dB(A)
80
60Hz
83
H
mm
508
mm
1050
mm
551
kg
130
3 AC 500V –15% to 600V +10%
DC 675V –15% to 810V +10%
46 to 64 (automatic frequency matching)
D.C.
888
1119
1023
1285
931
1169
240
1396
1754
60
1
4,03
5,40
0,55
1,0
80
82
83
82
H
K
508
800
1050
1400
551
550
130
260
Technical Data
1269
1633
1464
1880
1332
1711
1998
2566
5,87
6,65
1,0
1,0
82
82
82
82
K
K
800
800
1400
1400
550
550
260
300