Technical Data
Common
6SE70..-.....-0AA0 38-2EH85 41-0EH85 41-3EK85 41-8EK85
Rectifier
Rated voltage, rated frequency, rated current
Rated voltage
Input U
n
Output U
dn
Rated frequency f
n
Input
Output
Rated current I
n
Input (rms value) AC
Output (average) DC
Load class II acc. EN 60146-1-1
Rated output current average
Base load duration
Excess output current
average
Excess current duration
Losses, cooling, power factor
Power factor
Mains cosϕ
1N
Power dissipation
− Maximum
Cooling air requirement
Sound pressure level, dimensions, weight
Sound pressure
level of fan
Size
Width
Height
Depth
Weight app.
"Parallel units" (-0AD0) of size K for connecting in parallel have the same technical data as the corresponding
"basic units" (-0AA0). Please note the unit correspondence and notes of Section 3.7!
The permissible output current in parallel mode is reduced (due to current division between the power sections)
by 10 % as compared to the sum of the rated currents of the separate power sections.
14-2
ENGLISH
V
Hz
A
710
821
A
747
s
A
1121
s
kW
3,29
3
m
/s
0,55
50Hz
dB(A)
80
60Hz
83
H
mm
508
mm
1050
mm
551
kg
130
3 AC 380V –15% to 480V +10%
DC 510V –15% to 650V +10%
46 to 64 (automatic frequency matching)
D.C.
888
1156
1023
1333
931
1213
240
1396
1820
60
1
3,70
4,85
0,55
1,0
80
82
83
82
H
K
508
800
1050
1400
551
550
130
260
1542
1780
1620
2430
6,24
1,0
82
82
K
800
1400
550
300
Siemens AG
6SE7087-6AK85-0AA0
Common Rectifier
Operating Instructions