11.11.3
D21, circuit diagram prepared for speed actual value sensing (pulse encoder)
Category
Documentation
Function
The connection of the speed actual value sensing using an incremental encoder is shown in
the circuit diagram. The customer connection is realized at the TMC terminal adapter.
Connection
Table 11- 35 Terminal strip –X71 – connection for an incremental encoder
Terminal
41
42
43
44
45
46
47
48
Max. connectable cross-section: 1.5 mm
Commissioning
See the operating instructions of the SINAMICS DCM DC converter, SINAMICS DCM DC
converter List Manual, operating instructions of the SINAMICS DCM Cabinet, Chapter Signal
connections (Page 85).
Parameter assignment
Set p50083 = 2
SINAMICS DCM Cabinet
Operating Instructions, 04/2015, A5E36161239/RS-AA/001
Designation
Incremental encoder supply
Incremental encoder ground
Track 1 positive connection
Track 1 negative connection
Track 2 positive connection
Track 2 negative connection
Zero mark positive connection
Zero mark negative connection
2
Options
11.11 Documentation
Technical data
Incremental encoder