94
Technische Beschreibung
STANDARD Coag
HF voltage form
unmodulated sinusoidal AC voltage
Rated frequency
350 kHz (at RL = 500 ohms) ± 10%
Crest factor
1.4 (at RL = 500 ohms)
Rated load resistance
50 ohms
Max. HF peak voltage
190 Vp
Number of effects
8
Constancy of effects
automatic control of HF peak voltage
HF power limitation
5 Watt to 120 Watt in 1 Watt steps
Max. power output at
120 Watt ± 20%
rated load resistance
FORCED Coag
HF voltage form
pulse-modulated sinusoidal AC voltage
Rated frequency
350 kHz (at RL = 500 ohms) ± 10%
Crest factor
5.0 (at RL = 500 ohms)
Rated load resistance
500 ohms
Max. HF peak voltage
1800 Vp
Number of effects
4
Constancy of effects
automatic control of HF peak voltage
HF power limitation
5 Watt to 120 Watt in 1 Watt steps
Max. power output at
120 Watt ± 20%
rated load resistance
BIPOLAR STANDARD Coag / BIPOLAR STANDARD with AUTO STOP
HF voltage form
unmodulated sinusoidal AC voltage
Rated frequency 350 kHz
350 kHz (at RL = 500 ohms) ± 10%
Crest factor
1.4 (at RL = 500 ohms)
Rated load resistance
75 ohms
Max. HF peak voltage
190 Vp
Number of effects
8
Constancy of effects
automatic control of HF peak voltage
HF power limitation
1 Watt to 120 Watt in 1 Watt steps
Max. power output at
120 Watt ± 20%
rated load resistance
Technical description
Technical data