Herunterladen Inhalt Inhalt Diese Seite drucken

Object 1002H: Manufacturer Status Register; Object 1003H: Pre-Defined Error Field - TR-Electronic CANopen+Multi-Sensor LP-46-K Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.3 Object 1002h: Manufacturer status register

This object is not used by the measuring system, by read access the value is always "0".

7.4 Object 1003h: Pre-defined error field

This object saves the measuring system error occurred last and displays the error via
the Emergency object. Each new error overwrites an error which was stored before in
sub-index 1. Sub-index 0 contains the number of the occurred errors. Meaning of the
error codes see Table 17, page 182.
Writing 00h to sub-index 0 deletes the number of errors and the standard error field,
see also Emergency Error codes from page 181.
Index
1003h
Sub-index 0: Sub-index 0 contains the number of actual errors that are recorded
Sub-index 1: The error are composed of a 16 bit error code and a 16 bit additional
Unsigned32
Printed in the Federal Republic of Germany
01/20/2017
Sub-Index
Comment
0
number of errors
1
standard error field
in sub-index 1.
error information.
Byte 0
Byte 1
Error code
TR - ELA - BA - DGB - 0016 - 04
Type
Unsigned8
Unsigned32
Standard Error Field
Byte 2
Attribute
rw
ro
Byte 3
not supported
 TR-Electronic GmbH 2010, All Rights Reserved