CAUTION
On all WTX120 variants with an integrated display, the DKU port is blocked
with an additional notice label. The label must not be removed.
Notice
The shielding measures for connecting cables, that are specified throughout
the document, must be observed. If the shielding is inadequate this can cause
incoming or outgoing interferences which would impair functional safety.
4.4

Connecting the supply voltage

Apart from the primary PROFINET, EtherNet/IP, Profibus DP and Modbus
TCP interfaces, all the weighing terminal's connections are located on the
underside.
S The supply voltage is connected to terminal KL2.1 or KL2.3.
S The supply voltage can be connected to terminal KL2.2 or KL2.4 and trans­
mitted to the next weighing module. A maximum of eight weighing modules
can be connected in this way.
S The supply voltage is 12 V (–15%) to 30 V (+10%) at a max. current
consumption of 1.3 A. Only safety extra low voltages may be connected.
S The supply voltage connection is protected against polarity reversal.
WTX120
A04500_02_Y00_00 HBM: public