Supervisor mode
If you enter the target weight the monitor is automatically deactivated.
Information
Choose an increase in weight that is greater than the fluctuations caused by
the material escaping during the filling process.
When a break is detected:
S Coarse flow and fine flow are deactivated.
S Bit 6 (Alarm) is set to 1 in dosing status (SDO).
S Then if Alarm: Fill flow On is set, the alarm is triggered,
S dosing control switches to the stop status.

9.2.31 Lock out time fine flow

The time starts when the coarse flow cut-off point is reached. For the specified
time, the comparison of the actual weight against reaching of the fine flow cut-
off point is disabled. The time does not delay the filling process.
When the coarse flow shuts off, settling processes may occur that will already
cause the coarse flow cut-off point to be exceeded. You can prevent that with
this setting. Experience shows that the lockout time should be about 10 % of
the fine flow dosing time.