Note: The device must be restarted after changing the application
(Standard or Filler).
7.2

Limit switches

For more information on the keys required to access this menu group, go to
the
Navigation
Pilot.
Information
Limit switches are only available with the Application:Standard option.
The Limit switches function provides up to four independently adjustable limit
switches, each capable of monitoring one of two possible signal sources in four
different modes
Menu
Limit Switches
Source (LS1...LS4)
Mode (LS1...LS4)
WTX120
Key
Function/secondary selection
Toggle and select the desired source
Off
Net
Gross
Toggle and select the desired mode
Above Level
Below Level
Outside Band
Inside Band
A04500_02_Y00_00 HBM: public
Limit switch function deactivated
Net signal
Gross signal
For explanatory notes
see 7.2.1
For explanatory notes
see 7.2.2
For explanatory notes
see 7.2.3
For explanatory notes
see 7.2.4
Application
79