If the sensitivity of the load cell(s) used in a scale is known, a calibration
without weights can be carried out. The precondition for this is that a zero
balance of the unloaded scale can be carried out, which is almost always
possible in practice.
The size of the standardized signal under 100% load is equal to the sensitivity
of the load cell, or the averaged sensitivity of multiple load cells, meaning in
practice 2.00000mV/V or 3.00000mV/V, depending on the load cells.
WTX120
Parameters
Motion window
Motion count(er)
Filter size
Auto zero range
Pushbutton zero (+)
Pushbutton zero (–)
Power-up Zero
Overload
Incline switch
NTEP
Underload 20d
With taring
Onscreen typeplate
Update rate
Zero (mV/V)
LC capacity
No. of LCs
mV/V of LC1
A04500_02_Y00_00 HBM: public
Standard
Your calibration
value
0.5D
20
11
0.5D
2%
2%
OFF
9D
OFF
N
Y
Y
Y
225
0.00000
0
1
2.00000
Calibration