Profibus Dp Configuration - HBM WTX120 Bedienungsanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connection
Assignment
8
A
9
Tab. 4.7
Terminal assignment U601
Profibus status LEDs
D601
Green
Red
ON
OFF
OFF
ON
OFF
Flashing
cyclically
OFF
Flashing
acyclically
Tab. 4.8
D601 system failure (red/green)

4.10.1 Profibus DP configuration

In the Profibus device variants, the WTX120 works as a Profibus-DP slave,
forming an I/O interface with up to 64 inputs and outputs, or as a data interface
with up to 64 input words and 64 output words, and at a speed of 12 MBit/s.
The Profibus address is set in "Service Mode/.Config. Fieldbus".
To set the WTX120 Profibus DP device variant parameters, a GSD file is
required which you can download from our website
de/6304/wtx120-industrielles-eichfaehiges-waegeterminal/.
WTX120
Profibus DP meaning
A signal
COM_LED (system failure)
RUN; cyclical communication
Incorrect configuration of Profibus DP card
STOP; no communication; connection error
No configuration
A04500_02_Y00_00 HBM: public