PLC link
The following commands (bits in data word AW0) are processed in this way:
AW0
.0
.1
.2
.3
.4
.6
.7
.8
.11
.12
.14
.15
1)
"Standard" only
2)
"Filler" only

12.4.1 Measured values

The values for the net and gross measured value are continually updated, and
are available in input words 0 to 3. The display format is 32-bit integer. To
display measured values correctly in accordance with the calibration, the status
information in data word EW5 must be analyzed.
EW0+
-
EW1
EW2+
-
EW3
EW5
.4-6
.7-8
160
Tare
Gross/net
Delete dosing results
2)
Cancel dosing
2)
Start dosing
Zero balancing
Adjust zero load
Adjust maximum capacity
Transfer data
1)
Manual tare
Record weight
2)
Manual re-dosing
Net measured value
Gross measured value
Decimal places
Unit
A04500_02_Y00_00 HBM: public
2)
0-6
0=kg, 1=g,
2=t, 3=lb
WTX120