KL4
KL4
/D
11
L3+
L3–
12
Tab. 4.3
Connection of digital inputs and outputs and analog output
Important
Please observe the following when installing signal lines:
Signal lines connecting the digital inputs/outputs must be installed so that in­
ductive and capacitive interference from other lines, machines or electrical
devices is ruled out. Interference which changes the input/output signals might
lead to malfunctions and hazardous operating states.
Signal line cables must meet the following specifications:
S Shielded on both sides
S Flexible wires with wire end ferrules
S Cable resistance
Conductor cross-section 0.2mm
Line capacity
Rated voltage
Cable length
Information
To ensure optimal interference suppression of all injected frequencies, the
shield should be applied on both sides.
WTX120
AD
Comments
Comments
A/
Supply voltage outputs DO 2...DO 3
Reference potential in-/outputs DI  0...DI  3,
DO  2...DO  3
≤ 125 Ω/km
≤ 130 nF/km
≥ 250V
max. 15m
A04500_02_Y00_00 HBM: public
to max. 0.5mm
2
Installation
2
27