HBM WTX120 Bedienungsanleitung Seite 88

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Application
Menu
Output 1...8
86
Key
Function/secondary selection
The following functional settings are available
for configuration of the digital outputs:
Off
Manual
Coarse
Fine
Ready
Tol.+
Tol.-
Tol. Error Signals tolerance + has been
Alarm
DL1/DL2
Discharge
A04500_02_Y00_00 HBM: public
Deactivated
Manual set/reset via
Service Mode/Test
(see 16.4.3)
When activated, the coarse flow
valve is opened.
When activated, the fine flow
valve is opened.
When active, signals that the
filling process is complete.
Signals tolerance + has been
exceeded
Signals tolerance - has not been
reached
exceeded or tolerance - has not
been reached
Issues an alarm (see chap­
ter 9.2.11
"Alarm (Alarm:Empty)")
When the DL1/DL2 phase is
activated, the output is activated
during DL2
During the discharge phase
(weight and/or time controlled)
the relevant discharge actuator
is activated
WTX120