12.4.4 Weight storage

To enter the current measured value in the approved memory, the "Weight
storage" command (AW0 – bit 14) must be executed.
In "Filler" operating mode and when the Application->General setup->
Rec. weight=External option is activated, the filled weight must be confirmed
with this command or via a digital input.
AW0
.14
The last entry in the approved memory is automatically transferred into data
words EW9 – EW14.
EW9
Weight storage, day
EW10
Weight storage, month
EW11
Weight storage, year
EW12
Weight storage, seq. number
EW13
Weight storage, gross
EW14
Weight storage, net

12.5 Data word monitor

The data word monitor makes it possible to check the content of the input and
output data words during continuous operation. The monitor is called up with
the Info key.
Menu
Measured value display
Data word monitor
Output word 0-63
162
Transfer data
Record weight
Key
A04500_02_Y00_00 HBM: public
Function/secondary selection
Call up data word monitor - input words/
output words