Herunterladen Diese Seite drucken

Configuration Of The Remote Control - HBM WTX120 Bedienungsanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Menu
Config.
→ ETHERNET IP selected
Endian:
→ PROFIBUS DP selected
Address:
Information
An overview of the supported Modbus/TCP services is available in
chapter 4.12.3, page 42.
6.4.5

Configuration of the remote control

The IP addresses of the additional WTX units in the same network with no
display must be entered on the WTX120 with a display.
Switching between the master WTX120 (W1) and the configured WTX120
slaves is implemented on the master by simultaneously combining the Info and
Enter keys. The display of the WTX120 W1 (master) indicates the active slave
at the top left via WA=Slave1, WB=Slave2, WC=Slave3 ...
Configurations, adaptations, etc. can be carried out on the active slave in the
same way as on the master.
WTX120
Key
Fieldbus
Big
999
A04500_02_Y00_00 HBM: public
Function/secondary selection
Select the connection for the fieldbus
For variant with PROFINET:
PROFINET, Modbus TCP, None
For variant with EtherNET/IP:
ETHERNET IP, Modbus TCP, None
For variant with PROFIBUS DP:
PROFIBUS DP, Modbus TCP, None
Off
Not assigned
Select byte sequence
Enter slave address
Service mode
67