9.2.32 Dosing delay 1
The dosing delay time 1 (DL1) starts after the fine flow has been cut off (fine
flow cut-off point). At the end of this delay time 1, dosing delay 2 is started.
This time is signaled on the preconfigured control output (DL1/DL2) as the
delay prior to activation of the output by dosing delay 2 (DL2).
Information
The residual flow status bit is already set during dosing delay time 1, see also
16.2.32 Residuals.
9.2.33 Dosing delay 2
Dosing delay time 2 (DL2) is started after dosing delay 1 ends. At the end of
dosing delay 2 the residual flow time starts.
During the dosing delay time the control output (DL1/DL2) is activated.