Supervisor mode
Example
When filling sacks with a filling weight of 50kg, each sack is ejected after
checkweighing. During release, the sack clamp takes about 200g of material
from the filled sack, so that the released sack only weighs 49.8kg instead of
50kg.
In this case, enter 20 as the correction factor for Syst.diff. resulting in overfilling
of 200g (10 * P1 of SYD). As a result, the sack will initially be filled with 50.2kg,
and after release will have the target weight of 50kg.

9.2.25 Maximum dosing time

The dosing time starts when dosing starts (RUN command or digital input or
Enter key) and ends with the checkweighing (Finished signal). If the maximum
dosing time has been exceeded, the dosing process is aborted with an error,
and the coarse and fine flow outputs are deactivated (see chapter 9.2.11
"Alarm (Alarm:Empty)").

9.2.26 Tare delay(s)

You can use this time, for example, to blank out interferences from adding
sacks or containers. Set the tare delay so that any such disturbances have
been eliminated before taring begins.
When the filling process starts (RUN command or digital input or Enter key) the
tare delay starts. Taring is then carried out when the tare delay ends.
Requirements
In upward dosing, the empty weight and coarse flow cut-off point must not be
exceeded on starting.
Tare mode must be active (Tare Mode On).
Activation
Activate taring after a delay by way of the tare delay, specifying the delay time
to apply (also see chapter 9.2.15 "Empty weight")