The implementation of function codes 3 and 16 is recommended and suffices
to be able to use the full scope of WTX functions.
Function code 03: Read data from WTX (example: read weight)
Function code 16:Send settings to WTX (example: tare scale)

4.13 Ethernet connections

The Ethernet socket (LAN) is located on the underside of the device.
The Ethernet connection is made at the 'LAN' port by means of a shielded
RJ45 connector.
Only a shielded Ethernet cable (minimum CAT5e) with a maximum length of
80m may be used.
The preset IP address is 192.168.100.88 and the subnet mask 255.255.255.0.
Setting up a connection
1. Direct point-to-point connection of WTX120 and the PC using a RJ45 cable
Configure manual IP address & subnet mask on the connection PC (in sys­
tem control):
e.g. 192.168.100.81
255.255.255.0
The PanelX scan finds the connected WTX120 terminal
2. WTX120 in networking mode (multiple WTX terminals possible)
Assign manual IP address (see point 1.)
Configure WTX120 IP address and subnet mask in accordance with net­
work data.
The PanelX scan finds the connected WTX120 terminals.
3. Find WTX120 in the network
HBM device discovery tool also finds WTX120 in unconfigured networks.
The download is available on the WTX120 product page.