Herunterladen Diese Seite drucken

Customized Protocol - HBM WTX120 Bedienungsanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Continuous output/HBM protocol

11.2 Customized protocol

The data set is freely configurable. In the following table, x and y are
placeholders. If the condition is met, the character specified under x is
displayed.
If the condition is not met, the letter R specified under y is displayed instead.
Example: MB:R = in motion a B is displayed, otherwise an R.
Entry of the colon with the suffixed character y is optional. If the entry is not
made, a blank is left if the condition is not met.
Example: M~ = in motion the tilde character is displayed, otherwise a blank.
Weights are transferred with decimal points as separators. Unoccupied
(leading) positions are filled by blanks.
String
Mx:y
mx:y
Ox:y
ox:y
Zx:y
zx:y
148
14th - 15th character
Sent
Sends the character specified under x if the scale
is in motion, e.g. B, otherwise the character
specified under y.
Sends the character specified under x if the scale
is stable e.g.: R, otherwise the character specified
under y .
Sends the character specified under x if the scale
is overloaded, e.g.: U, otherwise the character
specified under y.
Sends the character specified under x if the scale
is not overloaded e.g.: U, otherwise the character
specified under y.
Sends the character specified under x if the scale
is in the zero range, e.g.: N, otherwise the
character specified under y.
Sends the character specified under x if the scale
is not in the zero range e.g.: N, otherwise the
character specified under y.
A04500_02_Y00_00 HBM: public
(Blank) = gross weight
CR and LF
Example
MB:R
mR:~
OU:N
oN:U
ZN:A
zA:N