7.3.2
Configuration of the digital inputs/outputs for
Application: Filler
The following functional settings are available for configuration of the digital
inputs/outputs:
Menu
Digital IO
Input 1...8
WTX120
Key
Function/secondary selection
The following functional settings are available
for configuration of the digital inputs:
Off
Tare
Stop
Start
Rec. weight Confirms the filled weight and
Re-dosing
Zero
A04500_02_Y00_00 HBM: public
Deactivated
If the input is set ("1"), the
application is tared
Stop the filling process
instantaneously.
Start the filling process, provided
all conditions are met.
saves it in the alibi memory.
(Only available if Applica­
tion->Rec. weight=External)
Manual re-dosing to make fine
adjustments to the filled weight
Set the gross weight of the
scales to zero
Application
85

Werbung

loading