Herunterladen Diese Seite drucken

Tare Mode; Emptying - HBM WTX120 Bedienungsanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Supervisor mode
9.2.7

Tare mode

This tare function is designed specially for batching processes.
Menu
Tare mode
9.2.8

Emptying

Emptying mode can optionally be used to monitor the end of the filling process.
During emptying, a digital output can be activated to control an emptying valve
for example.
Two variants are available:
Menu
Emptying
96
Key
Function/secondary selection
Off
On
Key
Function/secondary selection
Time
Weight
A04500_02_Y00_00 HBM: public
After starting (RUN command or digital
input or Enter key) no taring is carried
out. No preset tare delay time is
implemented for the tare.
If the measurement is lower than the
fine flow cut-off point after starting (RUN
command or digital input or Enter key),
the tare delay time is left to elapse be­
fore taring is carried out. Then the
coarse flow phase starts.
Time-controlled emptying.
Only the Time parameter deter­
mines the duration of emptying.
You can use the emptying time
parameter (parameter P1 > 0) to
activate emptying.
Weight-controlled emptying
The Empty weight parameter
specifies the emptying limit. The
emptying time is also used as a
maximum duration.
You can use the emptying time
parameter (parameter P1 > 0) to
activate emptying.