Supervisor mode
Meaning of parameter P1
A correction factor of 1 means that the difference between the actual weight
and target weight (either too much or not enough material added) will be in­
cluded in the next cut-off point at a rate of 100%. With a correction factor of
0.5, only 50% of the difference is included in the calculation.

9.2.10 Re-dosing

If the previously measured actual value is below the lower tolerance limit,
re-dosing is carried out. When optimization is active (parameter P1 > 0), the
result of a re-dosing operation does not change the cut-off points.
Re-dosing occurs with fine flow.
Menu
Re-dosing
98
Key
Function/secondary selection
Off
Re-dosing turned off
1
Re-dose if fine flow cut-off point < current
measured value < lower tolerance limit
When to re-dose?
At the start of the batching process
2
Re-dose if previously measured actual
weight < lower tolerance limit
When to re-dose
After checkweighing
3
Re-dose if
fine flow cut-off point < current measured
value < lower tolerance limit
When to re-dose?
At the start of the batching process
OR
Re-dose if previously measured actual
weight < lower tolerance limit
When to re-dose?
After checkweighing
A04500_02_Y00_00 HBM: public
WTX120