Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.11.1 Status LEDs

D600
Green
Red
ON
OFF
Flashing
OFF
OFF
ON
OFF
Flashing
Flashing
Flashing
OFF
OFF
Tab. 4.9
D600 system failure / module status
D601
Green
Red
ON
OFF
Flashing
OFF
OFF
ON
OFF
Flashing
Flashing
Flashing
OFF
OFF
Tab. 4.10 D601 bus failure / network status
WTX120
MS-LED (system failure / module status)
Device operational
Standby
Major fault
Minor fault
Self-test
No power
NS-LED (bus failure / network status)
Device operational
No connections
Duplicate IP
Connection timeout
Self-test
No power
No IP address
A04500_02_Y00_00 HBM: public
EtherNet/IP card functioning
correctly
EtherNet/IP card is NOT configured
(e.g. no IP address/DHCP mode
assigned)
Major fault cannot be reproduced
Reproducible minor fault (incorrect
or inconsistent configuration)
Self-test when starting the
operating system
No power supply or hardware fault
Connected to an EtherNet/IP
master
No existing connection to an
EtherNet/IP master, but has been
assigned an IP address
IP address of the EtherNet/IP card
is already being used
Existing connection cancelled
(time out)
Self-test when starting the
operating system
No voltage supply or no IP address
assigned
Installation
35

Werbung

loading