Supervisor mode
9.2.2
<info>
Presetting of what to do with the selected dosing parameter set. Setting op
tions:
Menu
<info>
9.2.3
Product no.
The current dosing parameter set and the associated dosing results are stored
under the entered product number and the associated product designation (see
chapter 9.2.4).
Up to 32 data sets can be stored. Value range : 1...32
9.2.4
Product
Each product number is linked to a product designation which is stored with the
dosing parameters and results. Twelve characters are available to describe
the product.
9.2.5
Dos.mode
Menu
Dos.mode
94
Key
Function/secondary selection
Edit
Delete
Print
Key
Function/secondary selection
Upwards
Downwards
A04500_02_Y00_00 HBM: public
Change the parameters
Delete the parameter set
Print the parameter set
Upward dosing = a container is
filled (see chapter 9.2.6)
Downward dosing = material is
taken from a filled container
(silo, tank (see chapter 9.2.6.1)