The filtration level can also be changed retrospectively in Service mode and
Master mode. This ensures that it is possible to change the filter strength
following calibration without damaging the calibration seal.
The filter setting in Service mode overwrites the calibration value every time
the application program is started. To check the validity of the setting, the
value in Service mode must be checked!
Menu
Auto Zero Range
PbZero (%) +
PbZero (%) -
PowerUp Zero +/-
WTX120
Key
0.5D
999
999
10%
A04500_02_Y00_00 HBM: public
Function/secondary selection
Automatic zeroing
This sets the range around the zero point in
which the weight value must be for automatic
zeroing to activate.
OFF
0.5D, 1.0D, 3.0D
Range of zero setting (+)
This sets the range above the power-up zero
point in which the scale can be zeroed by the
Zero key, and in which automatic zeroing
takes effect.
Range of zero setting (-)
This sets the range below the power-up zero
point in which the scale can be zeroed by the
Zero key, and in which automatic zeroing
takes effect.
Startup range of zero setting
This sets the range around the calibrated zero
point in which the scale is automatically
zeroed on power-up.
Power-up zero deactivated.
OFF
±2%, ±10%
Range size
Calibration
Switch off zeroing
Range size