12.1.2

Herstellerobjekte (manufacturer objects)

Index
Sub-
Bezeichnung
index
0x2nnn
0, 1, ... 9
Bitte beachten Sie
Kapitel
0x3001
0
Digital In actual values Read only
0x3002
0
Digital Out actual
values
0x3003
0
Digital Out set values
0x3004
0
Boolean Mux
0x3005
0
Boolean Demux
0x3006
0
Percentage set value
0x3007
0
Percentage actual
value 1
0x3008
0
Percentage actual
value 2
0x3011
0
Act. value Word 1
0x3012
0
Act. value Word 2
0x3021
0
Act. value Long 1
0x3022
0
Act. value Long 2
0x3111
0
Ref. value Word 1
0x3112
0
Ref. value Word 2
0x3121
0
Ref. value Long 1
0x3122
0
Ref. value Long 2
0x5F10
Gear factor
0
Highest sub-index
supported
1
Numerator
2
Denominator
3
Resync on Change
0x5F11
Phasing 1
0
Highest sub-index
supported
1
Offset
36
Bezeichnung
TxPDO2 mapping parameter
No. of mapped objects
1. mapped obj.
2. mapped obj.
3. mapped obj.
4. mapped obj.
5. mapped obj.
6. mapped obj.
7. mapped obj.
8. mapped obj.
TxPDO3 mapping parameter
No. of mapped objects
1. mapped obj.
2. mapped obj.
3. mapped obj.
4. mapped obj.
5. mapped obj.
6. mapped obj.
7. mapped obj.
8. mapped obj.
SDO Zu-
Datentyp
griff
Direkter Zugriff auf Frequenzumrichter-Parameter,
Lese/Schreibzugriff nur für SDO Übertragung
12.3.1 „Handhabung der Datensätze/zyklisches Schreiben"
Unsigned16
Read only
Unsigned16
Read/write
Unsigned16
Read only
Unsigned16
Read/write
Unsigned16
Read/write
Unsigned16
Read only
Unsigned16
Read only
Unsigned16
Read only
Unsigned16
Read only
Unsigned16
Read only
Unsigned32
Read only
Unsigned32
Read/write
Unsigned16
Read/write
Unsigned16
Read/write
Unsigned32
Read/write
Unsigned32
g)
Read only
Unsigned8
Read/write
Integer16
Read/write
Unsigned16
Read/write
Integer16
g)
Read only
Unsigned8
Read/write
Integer32
CM-EtherCAT
SDO Zugriff
Read/Write
Unsigned8
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
Read/Write
Unsigned8
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
Read/write
Unsigned32
PDO-
Factory
Map-
setting
ping
Herstellerspezifisch,
Tx
-
Tx
-
Rx
0
Tx
-
Rx
0
Rx
0
Tx
-
Tx
-
Rx
-
Rx
-
Rx
-
Rx
-
Tx
0
Tx
0
Tx
0
Tx
0
No
-
Rx
1
Rx
1
No
1
No
-
No
0x0001.0000 0x8000.0000
Datentyp
PDO-Mapping
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Nein
Min...Max
Zugeh.
Param.
-
-
-
-
0...0x1F
-
-
0...0xFFFF
-
0x8AD0...
-
0x7530
-
-
-
-
-
-
-
-
-
-
-
-
0...0xFFFF
-
0...0xFFFF
-
0...
-
0xFFFF.FFFF
0...
-
0xFFFF.FFFF
-
-
1...0x7FFF
p.1123
1...0xFFFF
p.1124
0...1
p.1142
-
-
p.1125 DS1
...
0x7FFF.FFFF
07/13