16.1.2
Zustandswort (Status Word) Überblick (ohne Sync Modes)
Die Tabellen auf dieser Seite geben einen Überblick über die Funktionen der Zustandswort Bits.
Standard (Keine
Bit
P ositionierung)
0
Ready to Switch On Ready to Switch On Ready to Switch On Ready to Switch On Ready to Switch On
1
Switched On
2
Operation enabled
3
Fault
4
Voltage enabled
5
Quick Stop
6
Switch On Disabled
7
Warning
8
9
Remote
10 Target reached
11
Internal limit active
12
13
14
15 Warning 2
M CI : I nterpol.
Bit
P osition M ode
0
Ready to Switch On Ready to Switch On Ready to Switch On Ready to Switch On Ready to Switch On
1
Switched On
2
Operation enabled
3
Fault
4
Voltage enabled
5
Quick Stop
6
Switch On Disabled
7
Warning
8
9
Remote
10 Target reached
11
Internal limit active
12 IP-mode active
13
14
15 Warning 2
07/13
P ositionierung
ohne M CI
Velocity M ode
Switched On
Switched On
Operation enabled
Operation enabled
Fault
Fault
Voltage enabled
Voltage enabled
Quick Stop
Quick Stop
Switch On Disabled
Switch On Disabled
Warning
Warning
Homing done
Remote
Remote
Target reached
Target reached
Internal limit active
Internal limit active
Target Pos. reached
Warning 2
Warning 2
M CI : Hom ing
M CI : Table tra-
M ode
vel record M ode
Switched On
Switched On
Operation enabled
Operation enabled
Fault
Fault
Voltage enabled
Voltage enabled
Quick Stop
Quick Stop
Switch On Disabled
Switch On Disabled
Warning
Warning
Motion Block in
Progress
Remote
Remote
Target reached
Target reached
Internal limit active
Internal limit active
Homing attained
In gear
Homing error
Following error
Warning 2
Warning 2
CM-EtherCAT
M CI :
M CI : P rofile
Velocity M ode
Switched On
Operation enabled
Fault
Voltage enabled
Quick Stop
Switch On Disabled
Warning
Remote
Target reached
Internal limit active
Speed
Max slippage error
Warning 2
M CI :
M ove aw ay
from Lim it Sw .
Switched On
Operation enabled
Fault
Voltage enabled
Quick Stop
Switch On Disabled
Warning
Remote
Target reached
Internal limit active
Warning 2
M CI : P rofile P o-
sition M ode
Switched On
Operation enabled
Fault
Voltage enabled
Quick Stop
Switch On Disab-
led
Warning
Remote
Target reached
Internal limit active
Set-point
acknowl.
Following error
Warning 2
M CI : Electronic
Gear: Slave
Switched On
Operation enabled
Fault
Voltage enabled
Quick Stop
Switch On Disabled
Warning
Phasing Done
Remote
Target reached
Internal limit active
Following error
Warning 2