Herunterladen Inhalt Inhalt Diese Seite drucken

Control Techniques Unidrive sp Kurzhandbuch Seite 29

Vorschau ausblenden Andere Handbücher für Unidrive sp:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Safety
Product
Mechanical
Information
Information
Installation
Parameter
0.23 Jog reference
0.24 Pre-set reference 1
0.25 Pre-set reference 2
OL> Pre-set reference 3
0.26
CL> Overspeed threshold
OL> Pre-set reference 4
0.27
CL> Drive encoder lines per
revolution
0.28 Keypad fwd/rev key enable
0.29 SMARTCARD parameter data
0.30 Parameter cloning
0.31 Drive rated voltage
Maximum Heavy Duty current
0.32
rating
OL> Catch a spinning motor
0.33
VT> Rated rpm autotune
0.34 User security code
0.35 Serial comms mode
0.36 Serial comms baud rate
0.37 Serial comms address
0.38 Current loop P gain
0.39 Current loop I gain
0.40 Autotune
0.41 Maximum switching frequency
0.42 No. of motor poles
OL & VT> Motor rated power
factor
0.43
SV> Encoder phase angle
0.44 Motor rated voltage
OL & VT> Motor rated full load
speed (rpm)
0.45
SV> Motor thermal time constant {4.15}
0.46 Motor rated current
0.47 Rated frequency
0.48 Operating mode selector
0.49 Security status
0.50 Software version
0.51 Action on trip detection
Key:
OL
Open loop
CL
Closed loop vector and Servo
VT
Closed loop vector
SV
Servo
Unidrive SP Short Form Guide
Issue Number: 2
Electrical
Getting
Menu 0
Installation
Started
Range( )
OL
VT
{1.05} 0 to 400.0 Hz
0 to 4000.0 rpm
{1.21}
±Speed_limit_max rpm
{1.22}
±Speed_limit_max rpm
±Speed_
{1.23}
freq_max
Hz/rpm
{3.08}
0 to 40,000 rpm
±Speed_
{1.24}
freq_max
Hz/rpm
{3.34}
{6.13}
OFF (0) or On (1)
{11.36}
0 to 999
nonE (0), rEAd (1), Prog (2),
{11.42}
AutO (3), boot (4)
{11.33} 200 (0), 400 (1), 575 (2), 690 (3) V
{11.32}
0.00 to 9999.99A
{6.09}
0 to 3
{5.16}
0 to 2
{11.30}
0 to 999
{11.24}
AnSI (0), rtu (1), Lcd (2)
300 (0), 600 (1), 1200 (2), 2400 (3),
4800 (4), 9600 (5), 19200 (6), 38400 (7),
{11.25}
57600 (8) Modbus RTU only, 115200 (9)
Modbus RTU only
{11.23}
0 to 247
{4.13}
0 to 30,000
{4.14}
0 to 30,000
{5.12}
0 to 2
0 to 4
{5.18}
3 (0), 4 (1), 6 (2), 8 (3), 12 (4), 16 (5) kHz
{5.11}
0 to 60 (Auto to 120 pole)
{5.10}
0.000 to 1.000
{3.25}
{5.09}
0 to AC_voltage_set_max V
0 to
0.00 to
{5.08}
180,000
40,000.00
rpm
rpm
{5.07}
0 to Rated_current_max A
0 to 3,000.0
0 to 1,250.0
{5.06}
Hz
Hz
OPEn LP (1), CL VECt (2),
{11.31}
SErVO (3), rEgEn (4)
{11.44}
L1 (0), L2 (1), Loc (2)
{11.29}
1.00 to 99.99
{10.37}
0 to 15
www.controltechniques.com
Running
Advanced
the motor
parameters
SV
OL
0.0
0.0
0 to 50,000
0
All voltage
ratings: 20
All voltage
ratings 40
0 to 6
0 (Auto)
0.0 to
359.9°
400V drive: EUR> 400, USA> 460
EUR>
1,500
USA> 1,800
0.0 to 400.0
Drive rated current [11.32]
EUR> 50.0
USA> 60.0
OPEn LP
(1)
{X.XX} Cloned advanced parameter
RW
Read/write: can be written by the user
RO
Read only: can only be read by the user
UL Listing
Diagnostics Appendix
Information
Default( )
VT
SV
0.0
0.0
0.0
0
1024
4096
OFF (0)
0
nonE (0)
0
0
rtU (1)
19200 (6)
1
200V drive: 75
400V drive: 150
575V drive: 180
690V drive: 215
200V drive: 1000
400V drive: 2000
575V drive: 2400
690V drive: 3000
0
3 (0)
6 (2)
6 POLE (3) RW
0.850
0.0
200V drive: 230
575V drive: 575
690V drive: 690
EUR>
1,450.00
USA>
1,770.00
20.0
CL VECt (2) SErVO (3)
0
Type
RW
RW
RW
RW
RW
RW
RW
RW
RO
RW
RO
RO
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RO
RW
29

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis