5.8.i. TOUCH SCREEN calibration
1. Select TOUCH SCREEN CALIBRATION then press the confirm button
(Fig. 41).
For greater precision, wear gloves when carrying out calibration.
2. Touch the 5 crosses displayed on the touch screen in sequence with your finger (Fig. 41a). Do not use a pointed object
such as a pencil to touch the screen, as this may cause miscalibration.
3. After calibrating, touch the display with your fingei (Fig.41b) and check that
the pointer follows the movements of your finger. Otherwise, repeat the
procedure.
4. Select one of the following:
-SAVE to save calibration
-CANCEL to exit calibration without saving
-REST ART CALIBR A TION to repeat the procedur
5.8.1. X AXIS calibration
This operation must ONLY be performed by author.ised personnel in the
following cases:
1.Replacing the x-axis potentiometer
2.Increase or decrease the rim-demounting tool distance set during previous
calibration
PROCEDURE
1. Mount the calibration template on the wheel support plate and lock it in
place with the cone without a plastic guard. Position it as shown in 2 Fig. 42
2. Access the SERVICE menu and select X AXIS CALIBRATION X (Fig. 42a). The
calibration
3. window opens (Fig. 42b).
Press RESET to cancel the previous calibration data.
146