Herunterladen Diese Seite drucken

Trouble Shooting - SATA AE1031H Bedienungsanleitung

3d-allrad-locator

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 193
-Clean and lubricate the upper and lower trolley guide (Fig. 51c):
Clean with environmentally-friendly solvents and lubricate with LIPLEX EP
2 lubricant or equivalent.
To carry out every two months.
-Check operation of the stop button (Fig. 51d):
If operating properly, the stop button will appear on the display.
Otherwise, contact technical assistance. To carry out every two months
-Contact the service network to check the belts and rubber pads:
Periodic check by the service network. To carry out every 7000 wheels-
-General machine check, contact the service network:
General periodic check by the service network. To carry out every year
In the event of a temporary mains power loss with the MOUNTING/DEMOUNTING tool between the wheel and the tyre,
proceed as follows once mains power has been restored:
-Restart the machine
-Press the RESET button on the display
The machine resumes operation normally from where it was stopped,
remembering the position of the tools
In the event of a prolonged electrical power out¬age, the wheel may
be released manually by in¬serting an 8 mm diameter steel pin in
the relative hole and turning anticlockwise (see Fig. 52)
ERRORS
E2
Communication software error
E17
Check serial connection between P3K and board
E19
Pump motor protection
E20
Perform machine calibration
E23
Motor overload circuit breaker tripped during wheel clamping
E24
Motor overload circuit breaker tripped during wheel
unclamping
E35
Lifter not in working position
E64
Error in p3k firmware
E132
Communication error with p3k
E163
Incomplete tool rotation or sensors not detected
E164
Wheel diameter not reached
E166
Tool work position not reached
E64
P3K firmware missing or incorrect
E45
Turntable translation potentiometer not detected
E60
Wait for machine to position
164
AE1031H

8.TROUBLE SHOOTING

中文
EN
DE
RU
KO
SOLUTION
Press OK to restart
Contact support service
Update p3k firmware again
contact technical support iferror persists
contact technical support iferror persists
Set position again
Contact support service
Contact support service
Contact support service
PT
JA
ES

Werbung

Fehlerbehebung

loading